-11-
Cell Voltage Monitor & Logger CellLog 8S
ALARM TRIGGER
Over Voltag
Low Voltage
Difference
Time Over
SAFETY TIMER
Minutes(1-999)
120
3) Monitor Safety Time Setting: Select【Safety Timer】, press < > and the screen shows:
<▲> or <▼> to increase/decrease, press < > to confirm amendment
and return. Press< > for 3 seconds to cancel amendment and return.
Setting range: 1-999 minutes
4) Alarm Trigger Settings: Select【Alarm Trigger】, press < > and the screen shows:
<▲> or <▼> to select items, press < > to shift select /,
press< > for 3 seconds to confirm amendment and return.
Select【Over Voltage】Cell or pack voltage are over HV setting value,
then it alarms.
Select【Low Voltage】Cell or pack voltage are lower LV setting value,
then it alarms.
Select【Difference】Cell voltage is over ▣V or the pack voltage
difference is over ▣P setting value, then it alarms.
Select【Time Over】 entering HOLD status time is over setting safety
time ,then it alarms.